As specially designed label for vacuum conditions from 1Pa to atmospheric pressure

Label and package
Color sample

Temperature range: 40~210℃
10pcs/pkg
Strictly under the control of the ISO9001:2008 QC system.
RoHS Compliant

The Temperature Label for Vacuums is a label-type temperature indicator for use under vacuum conditions (1Pa~ordinary pressure). Temperatures can be monitored without wiring or electric power  supply just by applying this label where needed. The color-changing area changes from light yellow to black when the response temperature is exceeded.

Color Transition Simulation

Product Features

  • The color changing temperature of the Temperature Label for Vacuums is calibrated under pressure down to 1Pa with dedicated measurement instruments.
  • 4-points temperature indicator for vacuum temperatures
  • Irreversible, single-use
  • Temp range: 40℃ to 210℃
  • Self-adhesive
  • Minimize precision errors under vacuum conditions
  • Low outgassing
  • Self-adhesive, easy to apply to various locations
  • Vacuum temperature monitoring
  • Irreversible & single use
Product nameTemperature
Combination(℃)
BeforeAfterAccuracyJAN Code
VL-4040-45-50-55Pale yellowBlack±2℃4582130423202
VL-6060-65-70-75Pale yellowBlack±2℃4582130423219
VL-8080-85-90-95Pale yellowBlack±2℃4582130423226
VL-100100-105-110-115Pale yellowBlack±2℃4582130423233
VL-120120-125-130-135Pale yellowBlack±2℃4582130423240
VL-140140-150-160-170Pale yellowBlack±4℃4582130423257
VL-180180-190-200-210Pale yellowBlack±4℃4582130423264

10 pcs/ package

Product nameTemperature
Combination(℃)
BeforeAfter
VL-4040-45-50-55Pale yellowBlack
VL-6060-65-70-75Pale yellowBlack
VL-8080-85-90-95Pale yellowBlack
VL-100100-105-110-115Pale yellowBlack
VL-120120-125-130-135Pale yellowBlack
VL-140140-150-160-170Pale yellowBlack
VL-180180-190-200-210Pale yellowBlack

10 pcs/ package

Sample Uses

Measure surface temperature of silicon wafer

Measure sputter temperature

Usage

Apply where temperature monitoring is required.

Warnings

  • Do not rub the color-changing part. This may cause abnormal color changes.
  • Apply on a flat surface. The temperature label for vacuums might fall off if applied on an uneven surface.
  • Do not bend the indicator or apply to a curved surface.
  • Do not cut the Temperature Label for Vacuums. This may reduce the durability of the product or cause abnormal color changes.

Effective lifetime

1 year after manufacturing
Outdoor use: The Temperature Label for Vacuums is not designed for outdoor use

Storage

Store unused indicators at room temperature under dark conditions. Avoid high temperatures and excessive humidity.

Precautions

Color Change
  • The color change temperature and its accuracy were determined at room temperature with a 2-3°C/min heating rate. Under special conditions, the color change temperature might differ.
  • The performance of irreversible temperature labels which change color at 130 or higher may be changed if it is exposed to temperatures in the 10from the specified temperature.

Applying the Label

  • Remove water, oil, rust and dust from the surface before applying the label. Contamination and uneven surfaces can cause labels to fall off or lead to abnormal color changes.
  •   Remove the release film, apply where temperature monitoring is required, and press the surface of the label gently with a finger or cloth. Strong rubbing might damage the label and affect performance (leading to abnormal color changes).
  •  Apply the labels on a flat surface. Labels are not designed to be applied on curved or corner surfaces.
  • Do not change the shape of the product. Cutting the product with a knife or reshaping it can reduce its durability and cause abnormal color changes.
Usage
  • Do not use electromagnetic induction heating devices such as microwave ovens under high pressure conditions.
  • Do not use the Temperature Label for Vacuums under plasticizer*-affected conditions. When the Temperature Label for Vacuums absorbs plasticizer*, the indicator may change color and/or the adhesion of the Temperature Label for Vacuums may be affected.
  • The insulated coating of electrical cables, terminal caps, and vinyl chloride resin may contain plasticizer.

Directive of RoHS

The temperature label for vacuums does not contain chemical substances prohibited by the RoHS directive.

Hazard identification

Immediate health, physical, and environmental hazards: The environmental properties of this product present a low environmental hazard. This product, when used under reasonable conditions and in accordance with the directions for use, should not present a health hazard. However, use or alteration of the product in a manner not in accordance with the product’s directions for use may affect the performance of the product and may present health and safety hazards.

Disclaimer

The information on this page is believed to be correct as of the date of issue. Neither the selling or producing company provides any warranties, expressed or implied, including, but not limited to, any implied warranty of merchantability or fitness for any particular purpose, course of performance, or usage of trade. The user is responsible for determining whether this product is fit for a particular purpose and whether it is suitable for the user’s method of use or application. Given the variety of factors that can affect the use and application of this product, some of which are uniquely within the user’s knowledge and control, it is essential that the user evaluate this product to determine whether it is fit for a particular purpose and suitable for the user’s method of use or application.

*Temperature label, RETOMARK, UVLABEL and DEWLABEL in all content including the digital catalog on this website are registered trademarks of NiGK Corporation in Japan.